1 -800-989-9518 201-847-1394

Intuitive Series

Digital Indicator

A unique adjustment system offers unparalleled benefits in our INTUITIVE l series of panel meters / controllers.

We strongly believe that this is the easiest programmable panel meter available anywhere IN THE WORLD to calibrate and set up.

If you program meters via a menu system, you will know how tedious and time consuming this can be.

Well, the INTUITIVE family eliminates the need for menus. The effect is dramatic, and has a pending patent.

Not only is the meter easier to adjust, the operating manual is much simpler and easier to understand than any needed for menu-driven meters.

And, you can DIRECTLY access just the parameter you want. If you wish to calibrate the zero, or the scaling, or the analog output, or the alarms, or the 10 point linearisation facility, you go directly to that setting, not down a long menu system via other parameters! We believe so strongly that this system offers more benefits to the user than any other setup scheme, we are designing it into our full range of meters and controllers.

Specifications

INTUITIVE-P:
Process Input

For 4-20mA, 0-10V, 1-5 etc. 24VDC excitation O/P, 60mA max
IINTUITIVE-L:
Load/Weight/Pressure:
Loadcell/Transducer Input, 4 or 6 wire. 10V 120mA excitation

Peak Hold Standard.

Input;      0-30mV           0-100mV

Options;

2 or 4 relays;      RS323;       RS485;       Analog Output...0-10V;  4-20mA

Description

Specifications:
Model Input/Display Ranges Accuracy Features
Intuitive-P
Process Meter
4-20mA, 0-10V, 1-5V, 0-10mA
 
Fully bipolar input/display
 
Display range max. 0-99990
 
Last digit selectable to count by 1, 2, 5, 10, 20, or 50.
 
Max. resolution 1 part in 60,000
0.05% of range
 
Span tempco ±50ppm/°C
 
Zero tempco ±50ppm/°C
 
Excitation voltage ±15%
Isolated 24V DC excitation rated at 60mA. 10 point user-defined linearization.
 
Intuitive-L
Loadcell Display
1mV/V to 5mV/V
 
Last digit selectable to count by 1, 2, 5, 10, 20 or 50.
 
Max. resolution 1 part in 60,000
 
Selectable variable filtering
0.05% of range of mV input
 
Span tempco ±50ppm/°C
 
Zero tempco ±50ppm/°C
 
Excitation voltage ±0.1%
Isolated 10V DC excitation rated at 120mA.
 
Drift canceling algorithm to compensate for sensor and indicator drift. Selectable remote or front panel Tare. Peak and Valley memories. 10 point user-defined linearization & programme memory option.
Plug-In Output Options - make it easy to expand your display:
2 Alarm O/P option 2 x SPST 5 Amp 240 VAC relays. Selectable hysteresis & In-Flight Compensation.
4 Alarm O/P option 4 x SPST 5 Amp 240 VAC relays. Selectable hysteresis & In-Flight Compensation.
Isolated Analog O/P Option Selectable 4-20mA, 0-10V or ±5V output. 250VAC Isolation.
Isolated Serial Data O/P Option RS232 or RS422 communications output. 250VAC Isolation.
Power Supply Choices:
95-265 VAC or 11-30 VDC, fully isolated, high efficiency. 8VA consumption max.

Ordering Guide:

Documentation